The Simulator is the top-level object in mrsimulator. The two main attributes of a Simulator object are spin_systems and methods, which hold a list of SpinSystem and Method objects, respectively. In addition, a simulator object also contains a config attribute, which holds a ConfigSimulator object. The ConfigSimulator object configures the simulation properties, which may be useful in optimizing simulations.

In this section, you will learn about the ConfigSimulator attributes. For simplicity, the following code pre-defines the plot function to use further in this document.

import matplotlib.pyplot as plt

# function to render figures.
def plot(csdm_object):
    plt.figure(figsize=(5, 3))
    ax = plt.subplot(projection="csdm")
    ax.plot(csdm_object.real, linewidth=1.5)
    ax.invert_xaxis()
    plt.tight_layout()
    plt.show()

ConfigSimulator

In mrsimulator, the default configuration settings apply to a wide range of simulations, including static, magic angle spinning (MAS), and variable angle spinning (VAS) spectra. In certain situations, however, the default settings are insufficient to represent the spectrum accurately. In this section, we use the simulator setup code below to illustrate some of these issues.

from mrsimulator import Site, Simulator, SpinSystem
from mrsimulator.spin_system.tensors import SymmetricTensor
from mrsimulator.method import SpectralDimension
from mrsimulator.method.lib import BlochDecaySpectrum

# Setup the spin system and method objects
Si29_site = Site(
    isotope="29Si",
    shielding_symmetric=SymmetricTensor(
        zeta=100,  # in ppm
        eta=0.2,
        alpha=1.563,  # in rads
        beta=1.2131,  # in rads
        gamma=2.132,  # in rads
    )
)
system = SpinSystem(sites=[Si29_site])

method = BlochDecaySpectrum(
    channels=["29Si"],
    rotor_frequency=0,  # in Hz
    spectral_dimensions=[SpectralDimension(count=1024, spectral_width=25000)]
)

# Create the Simulator object
sim = Simulator(spin_systems=[system], methods=[method])

Here, sim is a Simulator object which holds one spin system and one method. See Spin System and Method documentation for more information on the respective classes.


Integration Volume

The attribute integration_volume is an enumeration with two string literals, octant and hemisphere. The integration volume refers to the volume of a unit sphere over which the integrated NMR frequencies are evaluated. The default value is octant, i.e., the spectrum comprises of integrated frequencies from the positive octant of a unit sphere. mrsimulator can exploit the problem’s orientational symmetry, thus optimizing the simulation by performing a partial integration.

To learn more about the orientational symmetries, refer to Eden et al. [1]

Consider the \(^{29}\text{Si}\) site, Si29_site, from the above setup. This site has a symmetric shielding tensor with zeta and eta as 100 ppm and 0.2, respectively. With only zeta and eta (and zero Euler angles), we could exploit the symmetry of the problem and evaluate the frequency integral over the octant, equivalent to integration over a sphere. The non-zero Euler angles for this tensor break the symmetry, and integration over the octant will no longer be accurate.

sim.run()
plot(sim.methods[0].simulation)

(png, hires.png, pdf)

../../_images/simulator-3.png

Figure 74 Inaccurate simulation resulting from integrating over an octant when the spin system contains non-zero Euler angles.

To fix this inaccuracy, set the integration volume to hemisphere and re-simulate.

sim.config.integration_volume = "hemisphere"
sim.run()
plot(sim.methods[0].simulation)

(png, hires.png, pdf)

../../_images/simulator-4.png

Figure 76 Accurate CSA spectrum resulting from the frequency contributions evaluated over the top hemisphere.

Integration Density

The attribute integration_density controls the number of orientations sampled over the given volume. The resulting spectrum is the integrated NMR resonance frequency evaluated over these orientations. The total number of orientations, \(\Theta_\text{count}\), is

(37)\[\Theta_\text{count} = M (n + 1)(n + 2)/2\]

where \(M\) is the number of octants and \(n\) is value of this attribute. The number of octants is the value from the integration_volume attribute. The default value of this attribute, 70, produces 2556 orientations at which the NMR frequency contributions are evaluated.

sim.config.integration_density = 10
sim.run()
plot(sim.methods[0].simulation)

(png, hires.png, pdf)

../../_images/simulator-5.png

Figure 78 Low quality simulation from reduced integration density (=10).

sim.config.integration_density = 100
sim.run()
plot(sim.methods[0].simulation)

(png, hires.png, pdf)

../../_images/simulator-6.png

Figure 80 High quality simulation from increased integration density (=100).

Decreasing the integration density may decrease the simulation time for computationally intensive simulations but at the cost of spectrum quality. Generally, use a higher integration density for a high-resolution spectrum (i.e., a high-resolution sampling grid). For a low-resolution sampling grid, the spectrum may converge with a lower integration density.

Number of Sidebands

The number_of_sidebands attribute determines the number of sidebands evaluated in the simulation. The default value is 64 and is sufficient for most cases.

In certain circumstances, especially when the anisotropy is large or the rotor spin frequency is low, 64 sidebands might not be sufficient.

sim.methods[0] = BlochDecaySpectrum(
    channels=["29Si"],
    rotor_frequency=200,
    spectral_dimensions=[SpectralDimension(count=1024, spectral_width=25000)],
)
sim.run()
plot(sim.methods[0].simulation)

(png, hires.png, pdf)

../../_images/simulator-7.png

Figure 82 Inaccurate sideband simulation resulting from computing low number of sidebands.

Looking at the spinning sideband patterns, you see an abrupt termination of the sideband amplitudes at the edges. This inaccuracy arises from evaluating a small number of sidebands relative to the size of anisotropy. Increasing the number of sidebands will resolve this issue.

sim.config.number_of_sidebands = 90
sim.run()
plot(sim.methods[0].simulation)

(png, hires.png, pdf)

../../_images/simulator-8.png

Figure 84 Accurate sideband simulation after increasing the number of sidebands.

Conversely, 64 sidebands might be excessive, in which case reducing the number of sidebands may significantly improve simulation performance, especially in iterative algorithms, such as the least-squares minimization.

Decompose Spectrum

The attribute decompose_spectrum is an enumeration with two string literals, None and spin_system. The default value is None.

If the value is None (default), the resulting simulation is a single spectrum where the frequency contributions from all the spin systems are co-added. Consider the following example.

# Create two distinct sites
site_A = Site(
    isotope="1H",
    shielding_symmetric=SymmetricTensor(zeta=5, eta=0.1),
)
site_B = Site(
    isotope="1H",
    shielding_symmetric=SymmetricTensor(zeta=-2, eta=0.83),
)

# Create two single site spin systems
sys_A = SpinSystem(sites=[site_A], name="System A")
sys_B = SpinSystem(sites=[site_B], name="System B")

# Create a method representing a simple 1-pulse acquire experiment
method = BlochDecaySpectrum(
    channels=["1H"], spectral_dimensions=[SpectralDimension(count=1024, spectral_width=10000)]
)

# Create simulator object, simulate, and plot
sim = Simulator(spin_systems=[sys_A, sys_B], methods=[method])
sim.run()
plot(sim.methods[0].simulation)

(png, hires.png, pdf)

../../_images/simulator-9.png

Figure 86 The frequency contributions from each individual spin systems are combined into one spectrum.

When the value of decompose_spectrum is spin_system, the resulting simulation is a series of subspectra corresponding to individual spin systems. The number of subspectra equals the number of spin systems within the simulator object. Consider the same system as above, now run with decompose_spectrum as spin_system.

# sim already has the two spin systems and method; no need to reconstruct
sim.config.decompose_spectrum = "spin_system"
sim.run()
plot(sim.methods[0].simulation)

(png, hires.png, pdf)

../../_images/simulator-10.png

Figure 88 Each spin system’s frequency contributions are held in separate spectra.

Isotropic interpolation

The attribute isotropic_interpolation is an enumeration with two string literals, linear and gaussian. The default value is linear.

The value specifies the interpolation scheme used in binning purely isotropic spectrum.

Attribute Summaries

Table 13 The attributes of a Simulator object

Attribute Name

Type

Description

spin_systems

list

An optional list of SpinSystem objects.

methods

list

An optional list of Method objectss.

config

dict or ConfigSimulator

An optional ConfigSimulator object, or its dictionary representation.

Table 14 The attributes of a Simulator object

Attribute Name

Type

Description

number_of_sidebands

int

An optional integer greater than zero specifying the number of sidebands to simulate. The default is 64 sidebands.

integration_volume

str

An optional string representing the fraction of a unit sphere used in the integrated NMR frequency spectra. The allowed strings are octant and hemisphere. The default is octant.

integration_density

int

An optional integer greater than zero specifying the number of orientations sampled over the given volume according to the equation \(\Theta_\text{count} = M (n + 1)(n + 2)/2\), where \(M\) is the number of octants. The default value is 70.

decompose_spectrum

str

An optional string specifying the spectral decomposition type. The allowed strings are none and spin_system. The value of none produces one spectrum averaged over all spin systems, while spin_system produces a series of subspectra corresponding to individual spin systems. The default is none.

isotropic_interpolation

str

An optional string specifying the interpolation scheme used in binning purely isotropic subspectra. The allowed strings are linear and gaussian. The default is linear.